We propose a transverse load sensor with reconfigurable measurement accuracy based on a microwave photonic filter in the Ku band, incorporating a polarization-maintaining fiber Bragg grating. A prototype sensor with a reconfigurable measurement accuracy tuning range from 6.09 to 9.56 GHz/(N/mm), and corresponding minimal detectable load range from 0.0167 to 0.0263 N/mm, is experimentally demonstrated. The results illustrate that up to 40% manufacturing error in the grating length can be dynamically calibrated to the same corresponding measurement accuracy for the proposed transverse load sensor, by controlling the semiconductor optical amplifier’s injection current in the range of 154 to 419 mA.
Microwave photonics (MWP), focusing on the generation, processing and transport of signals in the far infrared, terahertz, microwave, and ultrahigh-frequency radio domains by photonics, offers many prominent advantages over classical radio frequency (rf) techniques [1]. An important application of MWP is the microwave photonic filter (MPF) [2], which has attracted considerable interest over the past decades thanks to beneficial features such as being wide-band, electromagnetic shielding, tunable, and lightweight [3]. Recently, we have also proposed an ultrawide-band MPF and demonstrated its high quality factor
Unlike optoelectronic oscillator (OEO) -based approaches in [10, 14], we propose a MPF structure for converting transverse load to a spectrum-filtering signal. This method avoids the measurement of frequency generation in the OEO schemes, and suppresses the measurement error coming from the drift in oscillating frequency due to the influence of environment temperature and vibration on the oscillatory cavity (
For these reasons, we propose a reconfigurable transverse load sensor based on our previous work [4], in a MPF incorporating a semiconductor optical amplifier (SOA). The proposed MPF along orthogonal polarization in an active loop operates at frequencies up to the Ku band, and provides a tunable free spectral range (FSR) from 15.44 to 19.44 GHz by control of the SOA’s injection current. A prototype of the equivalent second-order infinite-impulse response filter, with a
In this paper, a prototype sensor with a reconfigurable measurement accuracy tuning range from 6.09 to 9.56 GHz/(N/mm), and corresponding minimum detectable load range from 0.0167 to 0.0263 N/mm, is experimentally demonstrated. These mentioned tunability advantages can also be used to compensate for transverse load sensor errors, for example, even if the FBG length difference is up to 40%.
The PM-FBG works as a transverse load sensor. When a transverse force is applied to the PM-FBG it will be birefringent, due to differing refractive indices along the orthogonal directions. The load-induced birefringence
where
where and are respectively the delay time along transverse magnetic (TM) and transverse electric (TE) polarization directions in the PM-FBG,
The SOA works as a tunable birefringence compensator. Its birefringence effects contain a dynamic component and an intrinsic component. The former is determined by the operating state, and the latter is produced by the waveguide’s structure and material. When launch power or injection current is applied to the SOA, the change in the carrier density, rather than cross-gain modulation (XGM) effects [17], causes the orthogonal polarization signals to propagate at different group velocities and induce controllable, different delay times along the orthogonal directions. Thus, the total delay time of the proposed IIR filter along TE and TM polarization directions
where and are respectively the delay time along the TM and TE polarization direction in the SOA. The proposed MPF transfer function
where
∆
The schematic diagram of the proposed transverse load sensor based on a MPF is shown in Fig. 1. The output of a 1552-nm distributed-feedback (DFB) laser is modulated by a swept rf signal from a vector network analyzer (VNA), using a Mach-Zehnder modulator (MZM) with a 3-dB electrical bandwidth of 20 GHz. The modulated optical signal is sent to an erbium-doped fiber amplifier (EDFA) and a variable optical attenuator (VOA) to control the launch power, and a polarization controller (PC) afterward is used to generate two orthogonal polarization components along the TE and TM polarization directions. Then the orthogonal polarization signal is split into two paths by a 50:50 coupler via a circulator. One path is reflected from a PM-FBG, which is directly written in a 12-day hydrogenloaded (10 Mpa @ 24°C) germanium-doped PM fiber and has 99% reflectivity. In the experiment, two kinds of PM-FBGs produced by different types of PM fiber are used, which have different lengths (marked as PM-FBG1, with 10.0 cm length, and PM-FBG2, with 6.0 cm length). The PM-FBG works as a transverse load sensor, which is placed between two glass plates, to which the transverse force is applied, as shown in the lower right corner of Fig. 1. The other path goes into a single active loop consisting of a Fabry-Pérot SOA (FP-SOA) and a VOA. The SOA works as a tunable birefringence compensator and an amplifier to compensate for the loss in the loop. The delay time corresponding to the loop length is larger than the coherence time of the input laser, so that the structure is operated in an incoherent regime. A VOA afterward is used to maintain the optical power in the loop. Then the amplified orthogonal polarization signal is divided into two parts again by the coupler; one is sent to the circulator, and the other will reenter the loop to be delayed and obtain subsequent recursive taps. Thus, the orthogonal polarization signal circulating in the loop realizes two parallel first-order IIR filters with positive coefficient, after passing through a 45° polarizer and a photodetector (PD) incorporated with an optional electronic amplifier (EA).
The measurement shows that the loop length (not including the FP-SOA) of the prototype is about 1.25 m, and the corresponding delay time
Comparing those normal first-order IIR structured MPFs to the FSR less than 200 MHz (corresponding loop length is more than 1 m, due to pigtailed devices), the FSR of the proposed MPF is significantly increased to several GHz, in the Ku band. For instance, when
Benefiting from convenient control of the operating state of the FP-SOA, the transverse load sensor based on the proposed IIR filter affords a reconfigurable measurement accuracy. The FP-SOA can also works as a dynamic calibrator unit to compensate for individual length differences due to the manufacturing process of the PM-FBG. Thus the obtained sensing information from the PM-FBG is converted from the optical domain to the electrical domain, which can be directly detected by an electronic spectrum analyzer (ESA).
First, the MPF response without transverse load (
Secondly, the reconfigurable transverse-load measurement accuracy is experimentally demonstrated. Figure 3 shows that the MPF’s center-frequency offset is within a range of 1.0 GHz as the transverse load increases from 0 to 0.1 N/mm, when the FP-SOA injection current is set as shown in Fig. 2. The measured values are presented groups of squares in different colors in Fig. 3, and the slope of the corresponding linear fitting is in the range from −6.09 to −9.56. The absolute value of this slope is the proposed sensor’s measurement accuracy, which is in the range from 6.09 to 9.56 GHz/(N/mm). For instance, when changes from 0.44 to 0.60 GHz,
Although this accuracy is acceptable, the degradation is, indeed, obvious. The degradation is due to the increase of injection current in the SOA, and whether the accompanying SOA is working in the saturated state. The results illustrate that an injection current of 250 mA is the turning point of the SOA’s gain [4]. Exceeding this value, the SOA operates in the saturated regime. The FSR frequency keeps falling but gradually slows, as the SOA gain observably degrades. This results in an obvious degradation, from 0.0167 N/mm to 0.0263 N/mm, of the measurement accuracy based on FSR. Analysis shows that the reconfigurable ratio
The experimental results mentioned above are obtained when using PM-FBG1; next, PM-FBG2 with a different length (about 6.0 cm) is further used, to demonstrate the dynamic calibration performance for the proposed transverse load sensor. The difference in length between the two PM-FBGs can be regarded as the main source of manufacturing error, which is more than 40% here (but will not be so large in most real-world situations). Figure 4 shows the measured dynamic calibration curve as the transverse load increases from 0 to 0.1 N/mm, when the FP-SOA injection current is set to 419 mA. As an example, for PM-FBG1, when
Furthermore, other calibrated FP-SOA injection currents for PM-FBG2 are experimentally demonstrated. Figure 5 shows the measured dynamic calibration for the transverse load sensor while controlling the FP-SOA injection current in the range from 154 to 419 mA; here all of the results shown in Fig. 4 can be condensed into points A1, A2, and A3 in Fig. 5. The results illustrate that the slope of the MPF center frequency with transverse load for the compensated PM-FBG2 (blue triangles) agrees well with the corresponding value for PM-FBG1 (black squares), so the initial measurement accuracy for the sensor incorporating PM-FBG2 (red circles) are properly calibrated.
In this paper, an experimental investigation of a MPF-based transverse load sensor has been presented. An SOA is used to improve the performances of those traditional transverse load sensors incorporating FBGs, in aspects such as reconfigurable measurement accuracy and compensable error. By controlling the SOA’s injection current in the range from 154 to 419 mA, a prototype sensor with a reconfigurable measurement accuracy ranging from 6.09 to 9.56 GHz/(N/mm), and corresponding minimal detectable load ranging from 0.0167 to 0.0263 N/mm, is experimentally demonstrated. Considering the actual manufacturing error of the grating length, the same control method is also proved to be feasible for compensating to the same measurement accuracy of the transverse load sensor, for FBGs of different lengths, and the results illustrate that up to 40% manufacturing error in grating length can be dynamically calibrated.