검색 전체 메뉴
PDF
맨 위로
OA 학술지
Thickness Dependence of Ultraviolet-excited Photoluminescence Efficiency of Lumogen Film Coated on Charge-coupled Device
  • 비영리 CC BY-NC
  • 비영리 CC BY-NC
ABSTRACT

In order to investigate the ultraviolet-excited photoluminescence properties of phosphor coatings and their relationship to thickness, Lumogen coatings with different thicknesses were deposited on quartz substrates and charge-coupled device chips by thermal evaporation. The variation of the film thickness affected the crystallite size, surface roughness and fluorescence signal. It was found that the Lumogen coating with the thickness of 420 nm has the largest luminescent signal and conversion efficiency, and the corresponding coated charge-coupled devices had the maximum quantum efficiency in the ultraviolet. These results provided one key parameter for improving the sensitivity of Lumogen coated charge-coupled devices to ultraviolet light.


KEYWORD
Photoluminescence , Film thickness , Phosphor coating , Ultraviolet light
  • I. INTRODUCTION

    Silicon-based photodetectors with broadband spectral response, especially array devices of charge-coupled devices (CCD) and complementary metal oxide semiconductor (CMOS), have great desirable applications in spectrometer and space imaging, due to their reliability and compactness. However, the present CCDs have low quantum efficiency (QE) at Ultraviolet (UV) and deep Ultraviolet (DUV) wavelengths compared with that at visible wavelengths due to the absorption of the electronic gate structure deposited on the front or on the silicon substrate [1, 2]. Even though the thinning and back illuminated technique for UV responsive CCD can reduce the absorption loss of UV light, the high cost and difficulty in fabrication are still disadvantages in their applications in the various instruments [3]. It is possible to make CCD sensitive to UV light by simply incorporating a phosphor coating on the front-side of the CCD chip, which absorbs UV photons and re-radiates in the visible [4-11]. There are some kinds of fluorescent material for UV-responsive CCD [12-15] and solar cell efficiency enhancement [16]. There are also many demands for higher sensitivity of UV CCD for weak signal detection, such as fingerprint recognition and trace analysis. Essentially, the conversion efficiency and life expectancy of fluorescent coating films are determined by many factors [17, 18], such as crystal morphology, scattering and self-absorption, contaminants in the film, reflection at the air/film and other interfaces, etc. Thus, the parameters of phosphor coating need to be studied for sensitivity enhancement of the phosphor-coated device. It is worthwhile to consider the properties of fluorescent coatings prepared by a thermal evaporation method in the vacuum system as a function of thickness. In this paper, we fabricated a series of Lumogen films deposited by thermal evaporation on the quartz glass substrate and CCD, and discussed the influences of the thickness on fluorescence and conversion efficiency of Lumogen thin films as well as the quantum efficiency of the corresponding CCDs. Finally, we obtained the optimum thickness of the film.

    II. EXPERIMENT

    Phosphor coatings (Lumogen S0795, BASF) were deposited on the quartz substrates and charge-coupled device chips by thermal evaporation at room temperature. Prior to position in the deposition system, glass substrate slides were rinsed in acetone, ethanol and distilled water sequentially. Lumogen powder was packed into a molybdenum boat. The chamber was pumped to an ultimate vacuum pressure of 8 × 10-4 Pa before deposition. The deposition rate of 0.5 nm/s and the thickness for all films were monitored during deposition by using a quartz crystal monitor (SQC-310, INFICON).

    The crystal structures of the films were characterized by X-ray diffraction analysis (D8, Bruker). The data for phase identification was collected in a 2θ range from 10 to 60°. The surface morphology was measured by atomic force microscopy (XE-100, Park). The photoluminescence spectrum was acquired by a fluorescence spectrometer (Dual UV-NIR, Horiba). The conversion efficiency was obtained by a spectrophotometer with integrating sphere. The thickness of Lumogen thin films was measured by a stylus profilometer (XP-1, Ambios). The QE of CCD chips coated with Lumogen film was measured by a CCD & CMOS characterization system (MV-IS-2011, Enli). All the measurements were carried out at room temperature.

    III. RESULTS AND DISCUSSIONS

    X-ray diffractograms of the Lumogen films with different thickness are shown in Fig. 1. All films have two characteristic peaks in the spectrum at 2θ values of 11.6° and 12.8° (with an uncertainty of ±0.2°), representing crystalline d-spacing of 7.62 Å and 6.91 Å respectively. As the film thickness increases, the diffraction signal increases due to the growth of the materials incorporated in the diffraction process. Meanwhile, the full width at half maximum (FWHM) bandwidth decreases with the increase of the film thickness. According to the Scherrer formula [19], the decrement reflects the decrease in the internal microstrain within the films and an increase in the crystallite size. However, the increased crystallite size makes the film surface rough, as shown in Fig. 2. From Fig. 2 and Table 1, we reach a conclusion that surface roughness increases with the increase of the thickness, which leads to the increment of scattering loss, thus reducing the fluorescence efficiency of the Lumogen coating.

    [TABLE 1.] AFM test data of Lumogen films with different thicknesses

    label

    AFM test data of Lumogen films with different thicknesses

    Photoluminescence (PL) spectra here refer to the action of fluorescence related signal variation at a fixed wavelength of excitation light. Figure 3(a) shows the emission spectrum of samples with different film thicknesses excited at 250 nm. The peaks of fluorescence spectrum occur at about 528 nm, which is in the sensitivity region for most CCD/CMOS.

    As shown in Fig. 3(b), the light emission is changing with the increase of the film thickness. Meanwhile, an inflection point of PL signal occurred at about the thickness of 420 nm. It is known that visible luminescence is mainly due to the azomethine structure and a lot of double bonds of Lumogen molecules [20]. The emission signal is abruptly enhanced and slightly affected by low surface roughness, when the thickness is less than about 420 nm. With the increase of the thickness, the inner coating close to the substrate shows weaker fluorescent radiation because of limited UV penetration depth. On the other hand, the enhanced surface roughness increases the scattering loss of incident UV light and thus reduces the conversion efficiency. Thus the ultraviolet sensitivity cannot be improved by only increasing the film thickness infinitely.

    Conversion efficiency (CE) of phosphor coatings is the ratio of emitted light photon in the visible and exciting light photon in the ultraviolet. The integrating sphere is used in the spectrophotometer for the measurement of emitted light (visible) and incident light (ultraviolet). According to the definition of CE, the excitation photon number ninc after incident to the luminescence film and the emission photon number nemi emitted by the luminescence film after excitation, are measured. The CE of the Lumogen film is obtained if the property of emission spectrum of the different excitation wavelengths is considered.

    As shown in Fig. 4, the excitation light of wavelength λinc is incident on the integrating sphere and is measured by the detector. The excitation photons ninc can be obtained by

    image

    where h is Planck’s constant, c is the speed of light, and Einc is the energy of the excitation light.

    The excitation light through the film should be eliminated once the radiation photons are measured. Thus a long wave pass filter (LPF) is placed at the front of the detector to filter the excitation light. After the excitation light irradiates the film sample, the light emitted from the sample is transmitted to the integrating sphere through the base glass, and then the energy Eemi is detected by the detector after filtering out the interference light. The transmittance of the LPF is shown in Fig. 5. Considering the transmittance varying with the wavelength, the energy of emission wavelength through the filter can be expressed as

    image

    where the E(λi) and T(λi) are the energy and the transmittance of the emission wavelength, respectively.

    The transmittance of the filter is different for different wavelengths, so it is necessary to calculate the emission energy of different wavelengths by means of the emission spectrum of the luminescent film and the transmittance spectrum of the filter. The emission photon number of the corresponding wavelength is calculated, and then the total emission photon number is obtained.

    Emission spectra of luminescent thin films were obtained by a fluorescence spectrometer and the scaling factor k(λ) of the total energy of each sampling wavelength is given by the discrete method. The range of the emission wavelength is from λm to λn, and E(λi) is the energy of the emission at wavelength λi. Considering the transmittance of the emission wavelength, the ratio of energy of the wavelength to the total energy is obtained by

    image

    Here, the k(λi) value is equal to the kT(λi) value. The energy of the emission wavelength λi can be obtained based on

    image

    Thus, the number of radiation photons is

    image

    Then the conversion efficiency of the excitation wavelength λinc is

    image

    Figure 6 is the CE variation of the samples with different thicknesses of Lumogen film. Obviously, there is an optimal thickness of 420 nm at the four exciting wavelengths. The dependence of CE on the thickness of phosphor coatings is in good agreement with the PL spectrum and wavelength. Moreover, the CE is higher at shorter exciting wavelength than at longer exciting wavelength, which is favorable for fabrication of high sensitive UV-responsive CCD.

    Quantum efficiency is a fundamental property of CCD to indicate the amount of current that the CCD will produce when irradiated by photons of a particular wavelength. It is defined as the ratio of accumulated electrons to radiated photons of a single pixel, when the CCD chip is irradiated at a specific wavelength for a certain exposure time [21].

    A schematic of the measurement of QE is presented in Fig. 7. A collimated and uniform beam of light from a xenon lamp illuminates the CCD or CMOS. Before the measurement, the signal of the light is calibrated by a photo-radiometer. The computation of the QE requires the measurement of the mean gray values and the temporal variance of the gray together with the irradiance per pixel in the unit photons or pixels, is called the photon transfer method [21].

    A series of CCDs coated with different film thicknesses were fabricated. As shown in Fig. 8, it is found that the QE enhancement of the coated CCDs changes with different thicknesses in the UV wavelength. Meanwhile, there is not significant decrease in visible response and resolution by the presence of Lumogen. It is obvious that the coated CCD has the maximum QE when the thickness of the Lumogen film is about 420 nm. This is in agreement with the outcome of the measurement of CE. The QE in UV is typically 8% to 12%, while uncoated CCD is 0% at the range of 200 to 310 nm.

    IV. CONCLUSION

    The PL signal and CE of the phosphor coating strongly depend on the film thickness. The depth of the ultraviolet absorption and surface scattering of the phosphor coating are considered as essential factors. According to the XRD and AFM results, the surface roughness of Lumogen film increases with the increase of thickness. The Lumogen phosphor coating with the thickness of around 420 nm has the largest luminescent signal and conversion efficiency in the UV spectrum. Besides, CCDs coated with Lumogen film of the same thickness had the maximum quantum efficiency in the range of 190~340 nm. These results provided one key processing parameter for improving the sensitivity of Lumogen coated CCDs to ultraviolet light.

참고문헌
  • 1. 2003 Technical note on UV conversion coatings, Limited 507 google
  • 2. Alexander S. 2002 Phosphor coated UV-responsive CCD image sensor google
  • 3. Burke B. E. 1998 Large-area back-illuminated CCD image development [Exp. Astron.] Vol.8 P.31-40 google cross ref
  • 4. Cowens M. W. 1980 Coronene and lumogen as VUV sensitive coatings for Si CCD imagers: a comparison [Appl. Opt.] Vol.19 P.3327-3328 google
  • 5. Kristianpoller N., Dutton D. 1964 Optical properties of lumogen: a phosphor for wavelength conversion [Appl. Opt.] Vol.3 P.287-290 google cross ref
  • 6. Kristianpoller N., Knapp R. A. 1964 Some optical properties of sodium salicylate films [Appl. Opt.] Vol.3 P.915-918 google cross ref
  • 7. Blouke M. M. 1980 Ultraviolet down-converting phosphor for use with silicon CCD imagers [Appl. Opt.] Vol.19 P.3318-3321 google cross ref
  • 8. Du C. G., Sun L. Q., Ding Z. T. 2010 Experiment study of enhancing CCD ultraviolet response using Coronene [Opt. Tech.] Vol.36 P.753-757 google
  • 9. Jiang L. 2013 The spectrum of quantum dots film for UV CCD [J. Spectrosc.] Vol.2013 P.803-907 google
  • 10. Morrissey P. F. 1994 Vacuum-ultraviolet quantum efficiency of a phosphor-coated charge-coupled device [Appl. Opt.] Vol.33 P.2534-2538 google cross ref
  • 11. Franks W. A., Kiik M. J., Nathan A. 2003 UV-responsive CCD image sensors with enhanced inorganic phosphor coatings [IEEE Trans. Electron Devices] Vol.50 P.352-353 google cross ref
  • 12. Zhang D. W. 2010 Preparation and spectral characterization of lumogen coatings for UV-responsive CCD image sensors [Spectrosc. Spectral Anal.] Vol.30 P.1171-1174 google
  • 13. Zheng Y. F. 2009 The research of ultraviolet detection by using CCD [Proc. SPIE] Vol.7384 P.261-267 google
  • 14. Deslandes A. 2005 Characterization of PVD Lumogen films for wavelength conversion applications [Proc. SPIE] Vol.5649 P.616-626 google
  • 15. Jiang L. 2013 Preparation and characterization of UV-enhanced lumogen film by spin-coating technology [Spectrosc. Spectral Anal.] Vol.33 P.468-470 google
  • 16. Trupke T., Green M. A., Wurfel P. 2002 Improving solar cell efficiencies by down-conversion of high-energy photons [Appl. Phys.] Vol.92 P.1668-1674 google cross ref
  • 17. Catura R. C. 1998 Efficiency loss of lumogen-coated CCDs by exposure to ultraviolet and extreme ultraviolet photons [Proc. SPIE] Vol.3445 P.291-297 google
  • 18. Michael A. 2011 Stability of lumogen films on CCDs [Proc. SPIE] Vol.2415 P.204-210 google
  • 19. Lalitha S. 2004 Characterization of CdTe thin film-dependence of structural and optical properties on temperature and thickness [Sol. Energy Mater. Sol. Cells] Vol.82 P.187-199 google cross ref
  • 20. Fan M. G., Yao J. N., Tong Z. H. 2009 Molecular photochemistry and optical functional materials science google
  • 21. 2010 EMVA Standard 1288, Standard for characterization of image sensors and cameras, Release 3.0 11 P.5-6 google
이미지 / 테이블
  • [ FIG. 1. ]  XRD patterns of Lumogen thin films with the different thicknesses of (a) 240 nm, (b) 300 nm, (c) 360 nm, (d) 420 nm, and (e) 480 nm.
    XRD patterns of Lumogen thin films with the different thicknesses of (a) 240 nm, (b) 300 nm, (c) 360 nm, (d) 420 nm, and (e) 480 nm.
  • [ FIG. 2. ]  AFM micrograms of the films with thicknesses of (a) 300 nm, (b) 360 nm, (c) 420 nm, (d) 480 nm, (e) 540 nm, and (f) 600 nm.
    AFM micrograms of the films with thicknesses of (a) 300 nm, (b) 360 nm, (c) 420 nm, (d) 480 nm, (e) 540 nm, and (f) 600 nm.
  • [ TABLE 1. ]  AFM test data of Lumogen films with different thicknesses
    AFM test data of Lumogen films with different thicknesses
  • [ FIG. 3. ]  (a) photoluminescence spectrum of samples, where the excitation wavelength is 250 nm and the thicknesses of Lumogen films are 300 nm, 360 nm, 420 nm, 480 nm, 540 nm (b) Fluorescence peak signal of samples with different thicknesses of Lumogen.
    (a) photoluminescence spectrum of samples, where the excitation wavelength is 250 nm and the thicknesses of Lumogen films are 300 nm, 360 nm, 420 nm, 480 nm, 540 nm (b) Fluorescence peak signal of samples with different thicknesses of Lumogen.
  • [ ] 
  • [ FIG. 4. ]  Diagram illustrating the two configurations of the sphere required for the CE measurement. (a) Measurement of excited energy, (b) Measurement of emitted energy.
    Diagram illustrating the two configurations of the sphere required for the CE measurement. (a) Measurement of excited energy, (b) Measurement of emitted energy.
  • [ ] 
  • [ FIG. 5. ]  Transmittance of the filter with cut off wavelength of 399 nm, whose function is to filter the ultraviolet excitation light.
    Transmittance of the filter with cut off wavelength of 399 nm, whose function is to filter the ultraviolet excitation light.
  • [ ] 
  • [ ] 
  • [ ] 
  • [ ] 
  • [ FIG. 6. ]  The conversion efficiency of four samples with different thicknesses of Lumogen film (80 nm, 220 nm, 420 nm, and 580 nm) excited at wavelengths (220 nm, 250 nm, 300 nm, and 360 nm).
    The conversion efficiency of four samples with different thicknesses of Lumogen film (80 nm, 220 nm, 420 nm, and 580 nm) excited at wavelengths (220 nm, 250 nm, 300 nm, and 360 nm).
  • [ FIG. 7. ]  Schematic diagram of measuring system of QE.
    Schematic diagram of measuring system of QE.
  • [ FIG. 8. ]  The quantum efficiency of CCDs with different thickness of Lumogen films (blank, 160 nm, 310 nm, 350 nm, 420 nm, 1100 nm, 1500 nm). The detailed figure of QE in the range of 190 nm to 300 nm is on the top left corner.
    The quantum efficiency of CCDs with different thickness of Lumogen films (blank, 160 nm, 310 nm, 350 nm, 420 nm, 1100 nm, 1500 nm). The detailed figure of QE in the range of 190 nm to 300 nm is on the top left corner.
(우)06579 서울시 서초구 반포대로 201(반포동)
Tel. 02-537-6389 | Fax. 02-590-0571 | 문의 : oak2014@korea.kr
Copyright(c) National Library of Korea. All rights reserved.