Phosphodiesterases (PDEs) are a group of enzymes that catalyze the breakdown of cyclic adenosine monophosphate and cyclic guanosine monophosphate to their inactive form. PDE4 is the principal selective cyclic adenosine monophosphate metabolizing enzyme in inflammatory and immune cells which is highly expressed in leukocytes and other inflammatory cells involved in the pathogenesis of inflammatory lung diseases, such as asthma and chronic obstructive pulmonary disease (COPD).1 Roflumilast (RFL) is a second generation selective phosphodiesterase (PDE-4) inhibitor approved for the treatment of severe chronic obstructive pulmonary disease associated with chronic bronchitis. The IUPAC name for roflumilast is 3-(cyclopropylmethoxy)-
The International Conference on Harmonisation of Technical Requirements for Registration of Pharmaceuticals for Human Use (ICH) defines a degradation product as an impurity resulting from a chemical change in the drug substance brought about during manufacture and/or storage of the new drug product by the effect of, for example, light, temperature, pH, water, or by reaction with an excipient and/or the immediate container closure system.4 ICH guidelines also necessitate the drugs to be subjected to stress decomposition studies followed by identification and characterization of the degradation products (DP) which are formed 0.1%.5,6
A thorough literature survey has revealed that only a few studies have been reported for the degradation behaviour of roflumilast. Tarek S. Belal
However, there have been reports of process related impurities namely
Density Functional Theory (DFT) has been known to predict the fragmentation profile of protonated molecularions with reasonable accuracy.12 P. Wright
In this current study the chemical structures of the different DPs produced under acidic, alkali and oxidative stress conditions are investigated by liquid chromatography-high resolution mass spectrometry. Efforts have also been made to rationalize the fragmentation profile of the parent drug molecule by identifying the most favourable position of protonation and the changes in bond length consequent to it, DFT. The DPs were characterized by comparing their collision induced dissociation (CID) mass spectral data with that of the parent drug molecule of RFL. This rationalized fragmentation profile can also be extended to identify any other unknown transfor-mation products of RFL by comparing their daughter ions obtained under similar experimental condition.
HPLC grade acetonitrile and methanol were purchased from Merck India limited (Mumbai, India). Ultrapure water (18.2 MΩ) was prepared using a Milli-Q plus water purification system from Millipore (Bedford, MA, USA). Formic acid and standard of RFL were obtained from Sigma-Aldrich Corporation (Bangalore, India). Analytical reagent grade ammonium acetate, sodium hydroxide, hydrochloric acid and hydrogen peroxide were obtained from Qualigens India Limited (Mumbai, India)
All compound solutions were introduced into the ESI MS (electrospray ionisation mass spectrometry) source by high performance liquid chromatography (HPLC), Dionex ultimate 3000 (Thermo scientific, USA), using a hypersil BDS C18 column (150×4.6 mm, 5 µm, Thermo scientific, USA). A mobile phase consisting of A, 10 mM ammonium acetate adjusted to pH 3.2±0.05 with acetic acid and B, acetonitrile in gradient mode; T(min)/%B: 0/25, 10/60, 15/85, 20/85, 25/25, 30/25. Column temperature was maintained at 30 C and the flow rate was 1.0 mL/min. The samples were injected (10 µL) into the HPLC system in acetonitrile.
>
High-resolution mass spectrometry
The MS and MS/MS studies were performed on Thermofisher Q-exactive mass spectrometer (Thermo Electron, Bremen, Germany) using electrospray ionization source and orbitrap mass analyzer. Heated electrospray ionization source was used for ionization. The temperature of the heater was kept at 450℃ and capillary of the ESI interface at 250℃. Nitrogen was used both as sheath gas and auxiliary gas. The electro spray and tube lens were set at 4.5 kv and 90 V respectively. The mass spectrometer was operated in full scan MS with data dependent MS2 mode in positive polarity.
The selected range was from 100 to 1000 m/z and the resolution was 70,000 full width half maximum (FWHM) with an isolation window applied, followed by a data dependent scan at a resolution of 17,500 FWHM with the fragmentation energy applied. The target capacity of the C-trap was defined at 1×106 charges and the maximum injection time was limited to 50 ms.
Gas-phase basicity, 3D structure and bond length calculations were performed using DFT, calculations at the B3LYP level using the 6-31G* basis set, with Gaussian09. The optimised geometry for the neutral molecule was calculated, basic sites were then protonated and the relating minimum energy geometry calculated for each possible structure. The energy differences between the most favourable cation (highest negative energy value in Hartrees) and all others were converted from Hartrees into kcal/mol using the conversion factor of 627.503.
>
Sample preparation and degradation studies
Standard solution of roflumilast (100 µg/mL) was prepared by dissolving it in acetonitrile. Stress degradation sample, acidic (1 N HCl, 80℃, 6 h), alkaline (1 N NaOH, 80℃, 6 h) and oxidative (30% H2O2, 80℃, 6 h) were prepared by dissolving 10 mg of sample in 1 mL of acetonitrile, followed by the addition of 2 mL 1 N HCl, 3 mL 1 N NaOH and 3 mL 30% H2O2 respectively. All the sample solutions were neutralized and volume made up to 10 mL with acetonitrile prior to their injection into the mass spectrometer.
The drug exhibited degradation under acidic, alkali and oxidative stress conditions. The results of the degradation study have been summarized in Table 1.
The retention times (RT), measured masses, predicated elemental compositions, theoretical exact masses, mass errors and major fragment ions of degradation products (DP)
In an attempt to identify the DPs by mass spectral analysis it is highly desirable to have a clear understanding of the fragmentation pathway of parent drug RFL. Under ESI conditions RFL underwent protonation at the nitrogen atom of the pyridine ring and the position of protonation has also been supported by DFT calculations. The results of DFT calculation for the energies of different protonation sites has been depicted in Figure 1. The protonated molecular ion of RFL measured accurately to be m/z 403.0449 Da and produced key fragment ions at m/z 367.0686 Da, 348.9975 Da, 241.0687 Da, 187.0213 Da and 163.9676 Da. The most abundant product ion formed at m/z 241.0687 Da due to loss of 3, 5-dichloropyridine (C5H3Cl2N, 146.9643) by the cleavage of C-N, which further underwent loss of methylene cyclopropane (C4H6, 54.047 Da) to generate fragment ion at m/z 187.0213 Da. DFT optimized structure of the protonated molecular ion of roflumilast also indicated elongation of C-N bond as depicted in Figure 2. The formation product ion at m/z 348.9975 Da is due to loss of methylene cyclopropane (C4H6, 54.047 Da), which in turn under goes rearrangement with a neutral loss of 185 Da to produce the cation of 3,5-dichloropyridin-4-ol.The schematic presentation of the fragmentation profile of roflumilast is shown in Figure 3a.
DP-1 formed during alkaline degradation showed its protonated molecular ion at m/z 162.9821 Da and underwent fragmentation by losing a molecule of hydrochloric acid to produce a product ion at m/z 90.9777 Da, as shown in Figure 3b. Based on the mass spectra data DP-1 identified as 3, 5-dichloropyridin-4-amine.
DP-2 with a measured accurate mass of m/z 348.9946 Da formed during acidic as well as oxidative stress conditions. The characteristic isotopic pattern of two chlorine atoms in the mass spectra and product ion spectra containing diagnostic fragment ions of m/z 163.9676 Da, 313.0208 Da (Figure 3c) evidently supported it to be
DP-3 was formed under alkaline as well as oxidative stress conditions and showed its protonated molecular ion at m/z 353.0453 Da with characteristic isotopic pattern of two chlorine atoms. The diagnostic product ions formed at m/z 162.9838 Da and 191.0718 Da by the neutral loss of 3-(cyclopropylmethoxy)-4-(difluoromethoxy) benzaldehyde and 3,5-dichloropyridin-4-amine evidently supported it to be formed by the loss of CHF2 side chain from the molecule of roflumilast. Based on this mass spectral analysis as discussed above and depicted in Figure 3d, the most plausible structure of DP-3 has been proposed as
During oxidative stress study degradant formed with an accurate mass of m/z 419.0361 Da which is 16 Da higher than that of RFL and showed isotopic pattern confirming the presence of two chlorine atoms, is assigned the code name DP-4. The product ions formed in DP-4 are identical with that of RFL and exhibited similar neutral losses. Based on this the most possible structure of DP-4 is proposed to be the
Roflumilast was subjected to stress study and found to be sensitive in alkaline, acidic and oxidative environment. A rationalized approach based on DFT and comparative high resolution mass spectral analysis with product ion profiling was used for rapid identification of the degradation products. The four degradation products have been identified as 3,5-dichloropyridin-4-amine,